Preset Counters

2 Digit Preset Counter

DIGIT 2 Digit
NO. OF STAGES 1 Stage
DISPLAY 3-½ Digit, 7 Segment .56″ Height; Red L.E.D.
COUNT SETTING BY Thumb Wheel
RESET By Switch Provided on Front Panel
(Pulse Width 1µ Sec.(Min.)
SENSOR SUPPLY DC 12V ± 10% 50mA max. (Ripple 5% Max.)
INPUT SIGNAL SYSTEM Contact, Opto Coupler, Proximity Switch, Limit Switch, High/Low Voltage
RELAY CONTACT 5 Amp. Max. at 230V AC (Non InductiveLoad)
MAX. COUNTING SPEED 5 KHz
RESOLUTION 1 Count
RELAY CONTACT 5 Amp. Max. at 230V AC (Non Inductive)
COUNT MODE (OUTPUT) Auto or Manual User Selectable (optional)
POWER SUPPLY 180 – 230V AC ± 10% 60/50Hz
BACKUP POWER FOR MEMORY 6-72 Hours
COUNT MODE (INPUT) Up Counting/Down Counting or Both
POWER SUPPLY 180 – 230V AC ± 10% 60/50Hz
AMBIENT TEMP. / HUMIDITY 0 – 50°C, 35-85% RH.
DIMENSIONS 72(H)x72(W)x110mm(D)

Preset Counter manufacturers Supplier Dealer Nashik Maharashtra

4 Digit Preset Counter

DIGIT 4 Digit
NO. OF STAGES 1 Stage
DISPLAY 3-½ Digit, 7 Segment .56″ Height; Red L.E.D.
COUNT SETTING BY Thumb Wheel
RESET By Switch Provided on Front Panel
(Pulse Width 1µ Sec.(Min.)
SENSOR SUPPLY DC 12V ± 10% 50mA max. (Ripple 5% Max.)
INPUT SIGNAL SYSTEM Contact, Opto Coupler, Proximity Switch, Limit Switch, High/Low Voltage
RELAY CONTACT 10 Amp. Max. at 230V AC (Non Inductive)
MAX. COUNTING SPEED 5 KHz
RESOLUTION 1 Count
RELAY CONTACT 5 Amp. Max. at 230V AC (Non Inductive Load)
COUNT MODE (OUTPUT) Auto or Manual User Selectable (optional)
POWER SUPPLY 180 – 230V AC ± 10% 60/50Hz
BACKUP POWER FOR MEMORY 6-72 Hours
COUNT MODE (INPUT) Up Counting/Down Counting or Both
POWER SUPPLY 180 – 230V AC ± 10% 60/50Hz
AMBIENT TEMP. / HUMIDITY 0 – 50°C, 35-85% RH.
DIMENSIONS 96(H)x96(W)x110mm(D)

Preset Counter manufacturers Supplier Dealer Nashik Maharashtra

3 Digit Preset Counter

DIGIT 3 Digit
NO. OF STAGES 1 Stage
DISPLAY 3-½ Digit, 7 Segment .56″ Height; Red L.E.D.
COUNT SETTING BY Thumb Wheel
RESET By Switch Provided on Front Panel
(Pulse Width 1µ Sec.(Min.)
SENSOR SUPPLY DC 12V ± 10% 50mA max. (Ripple 5% Max.)
INPUT SIGNAL SYSTEM Contact, Opto Coupler, Proximity Switch, Limit Switch, High/Low Voltage
RELAY CONTACT 5 Amp. Max. at 230V AC (Non Inductive)
MAX. COUNTING SPEED 5 KHz
RESOLUTION 1 Count
RELAY CONTACT 5 Amp. Max. at 230V AC (Non InductiveLoad)
COUNT MODE (OUTPUT) Auto or Manual User Selectable (optional)
POWER SUPPLY 180 – 230V AC ± 10% 60/50Hz
BACKUP POWER FOR MEMORY 6-72 Hours
COUNT MODE (INPUT) Up Counting/Down Counting or Both
POWER SUPPLY 180 – 230V AC ± 10% 60/50Hz
AMBIENT TEMP. / HUMIDITY 0 – 50°C, 35-85% RH.
DIMENSIONS 96(H)x96(W)x110mm(D)

Preset Counter manufacturers Supplier Dealer Nashik Maharashtra

Programmable Preset Counter

DIGIT 4,5 Digit, Dual Display
DISPLAY Upper:3-½ Digit, 7 Segment .56″; Red L.E.D.
Lower: 3-½ Digit, 7 Segment .56″ Green L.E.D.
NO. OF STAGES 1, 2 Stage
COUNT SETTING BY Front Keyboard
RESET By Switch Provided on Front Panel
(Pulse Width 1µ Sec.(Min.)
SENSOR SUPPLY DC 12V ± 10% 50mA max. (Ripple 5% Max.)
INPUT SIGNAL SYSTEM Contact, Opto Coupler, Proximity Switch, Limit Switch, High/Low Voltage (Optional)
INPUT SIGNAL SCALER Signal can be multiplied or divided through software
MAX. COUNTING SPEED 5 KHz
RESOLUTION 1 Count
RELAY CONTACT 10 Amp. Max. at 230V AC (Non Inductive)
COUNT MODE (OUTPUT) Programmable (optional)
BACKUP POWER FOR MEMORY 10 Years (Semi-permanent)
COUNT MODE (INPUT) Up Counting/Down Counting or Both
POWER SUPPLY 180 – 230V AC ± 10% 60/50Hz
AMBIENT TEMP. / HUMIDITY 0 – 50°C, 35-85% RH.
DIMENSIONS 96(H)x96(W)x140mm(D)
BODY TYPE ABS
Lock facility available on request

Preset Counter manufacturers Supplier Dealer Nashik Maharashtra